CUT OFF MODE 150 means the user has requested the software to consider 150 modes for the dynamic analysis. By default the software considers 6 modes and in case more number of modes are required to get enough mass participation (greater than 90% is recommended by most codes), user can do so by using the CUT OFF MODE command. More details are available in technical reference section 5.30.1.